Scribe logoScribeNotes & practice
Sign inStart free
  1. Notes
  2. ›AQA A-level Physics
  3. ›3.8 Nuclear physics
  4. ›3.8.1.8 Safety aspects

AQA A-level Physics · Section 3.8 · Nuclear physics

3.8.1.8 Safety aspects

Describe the main risks of ionising radiation, explain how exposure is reduced, and interpret count-rate data on distance and shielding.

  • 5 min read
  • 5 parts
  • 10 questions
  • Draft
Start a Quick 5 on this topic→Jump to the 10 questions
1/5Ionising radiation damages living cells
  1. 1Ionising radiation damages living cells
  2. 2Background radiation must be subtracted from measurements
  3. 3Increasing distance from a source sharply cuts exposure
  4. 4Thicker shielding absorbs more radiation
  5. 5Safe handling combines limits, monitoring and careful storage
  6. Check your recall
  7. Practice: 10 questions
1

Part 1 of 5: Ionising radiation damages living cells

Radiation from radioactive sources cannot be seen or felt. An ion is an atom or group of atoms with a net charge from losing or gaining electrons. Radiation with enough energy to remove electrons from atoms or molecules is ionising radiation.

Alpha, beta and gamma radiation can all ionise. In living tissue, this can damage DNA. A damaged cell may die, or it may divide in an uncontrolled way and lead to cancer.

Penetration of the three radiations

RadiationIonising powerStopped by
AlphaStrongPaper or a few cm of air
BetaModerateA few mm of aluminium
GammaWeakThick lead reduces it but never stops it
Radiation
Alpha
Ionising power
Strong
Stopped by
Paper or a few cm of air
Radiation
Beta
Ionising power
Moderate
Stopped by
A few mm of aluminium
Radiation
Gamma
Ionising power
Weak
Stopped by
Thick lead reduces it but never stops it

Common mistake

Alpha radiation is not harmless because paper stops it. If an alpha source is swallowed or inhaled, it ionises tissue directly.

Key terms · tap one for its definition

ion

An ion is an atom or group of atoms with a net charge from losing or gaining electrons.

ionising radiation

Ionising radiation carries enough energy to remove electrons from atoms or molecules.

Part 1 done

2

Part 2 of 5: Background radiation must be subtracted from measurements

Even with no source nearby, a detector still clicks. The ionising radiation always present from natural and artificial sources is background radiation. Rocks, the air and cosmic rays all contribute.

Measure the background first, with no source present. A long counting time reduces random variation. Then subtract the background count rate from each reading to get the corrected count rate. Background varies from place to place and from day to day. Measure it where and when the experiment is done. Without this correction, a source would seem more active than it really is.

Worked example

Correcting a count rate

A detector records 252 counts in 3.0 min3.0\,\mathrm{min}3.0min with a source present. With no source it records 45 counts in 3.0 min3.0\,\mathrm{min}3.0min. Determine the corrected count rate.
  1. 1
    Measured count rate: 2523.0 min=84 min−1\frac{252}{3.0\,\mathrm{min}}=84\,\mathrm{min^{-1}}3.0min252​=84min−1.
  2. 2
    Background count rate: 453.0 min=15 min−1\frac{45}{3.0\,\mathrm{min}}=15\,\mathrm{min^{-1}}3.0min45​=15min−1.
  3. 3
    Corrected count rate equals measured minus background: 84 min−1−15 min−1=69 min−184\,\mathrm{min^{-1}}-15\,\mathrm{min^{-1}}=69\,\mathrm{min^{-1}}84min−1−15min−1=69min−1.

Answer: The corrected count rate is 69 min−169\,\mathrm{min^{-1}}69min−1.

Key terms · tap one for its definition

background radiation

Background radiation is the ionising radiation always present in the environment from natural and artificial sources.

corrected count rate

The corrected count rate is the measured count rate minus the background count rate, in min−1\mathrm{min^{-1}}min−1.

Part 2 done

Quick check

One question on the part you just read

Easy

Identify the correct description of an ion.
Show answer and explanation

Answer: A · Worked explanation

An ion forms when an atom or group of atoms loses or gains electrons, so it has a net charge. Ionising radiation creates ions by removing electrons. A particle with no net charge is not an ion, since the charge is what defines it.
3

Part 3 of 5: Increasing distance from a source sharply cuts exposure

The simplest precaution is to stand further away. For a small source of gamma rays, intensity falls as distance grows. The inverse square law states that intensity III is proportional to 1x2\frac{1}{x^2}x21​, where xxx is the distance from the source.

Doubling the distance therefore cuts the intensity to one quarter. Alpha and beta radiation are absorbed by air, so this law is used for gamma rays. Handling sources with tongs and limiting the time of exposure also reduce exposure, because total exposure builds up over time.

Worked example

Moving away from a source

A small gamma source gives a corrected count rate of 240 min−1240\,\mathrm{min^{-1}}240min−1 at 0.50 m0.50\,\mathrm{m}0.50m. Calculate the corrected count rate at 2.0 m2.0\,\mathrm{m}2.0m.
  1. 1
    Intensity is proportional to 1x2\frac{1}{x^2}x21​, so I2=I1(x1x2)2I_2=I_1\left(\frac{x_1}{x_2}\right)^2I2​=I1​(x2​x1​​)2.
  2. 2
    Substitute: I2=240 min−1×(0.50 m2.0 m)2=240 min−1×0.0625I_2=240\,\mathrm{min^{-1}}\times\left(\frac{0.50\,\mathrm{m}}{2.0\,\mathrm{m}}\right)^2=240\,\mathrm{min^{-1}}\times0.0625I2​=240min−1×(2.0m0.50m​)2=240min−1×0.0625.

Answer: The corrected count rate is 15 min−115\,\mathrm{min^{-1}}15min−1.

Key term

inverse square law

The inverse square law states that the intensity of radiation from a small source is proportional to 1x2\frac{1}{x^2}x21​, where xxx is distance.

Part 3 done

4

Part 4 of 5: Thicker shielding absorbs more radiation

Distance is not always possible, so absorbing material can be placed between a source and people. This shielding reduces the radiation that reaches them. The table earlier showed that each radiation needs a different absorber. Lead and concrete are common choices for gamma sources, but gamma rays are never absorbed completely.

For gamma rays, each equal thickness of material removes the same fraction. The half-value thickness is the thickness that halves the intensity passing through. The pattern repeats for every further thickness of the same size.

Worked example

Half-value thickness of lead

A gamma source has a corrected count rate of 320 min−1320\,\mathrm{min^{-1}}320min−1 with no absorber. With 1.0 cm1.0\,\mathrm{cm}1.0cm of lead it is 160 min−1160\,\mathrm{min^{-1}}160min−1, and with 2.0 cm2.0\,\mathrm{cm}2.0cm it is 80 min−180\,\mathrm{min^{-1}}80min−1. Determine the half-value thickness and predict the rate with 3.0 cm3.0\,\mathrm{cm}3.0cm.
  1. 1
    The rate halves from 320 to 160 over 1.0 cm1.0\,\mathrm{cm}1.0cm.
  2. 2
    It halves again from 160 to 80 over the next 1.0 cm1.0\,\mathrm{cm}1.0cm, so the half-value thickness is 1.0 cm1.0\,\mathrm{cm}1.0cm.
  3. 3
    Three half-value thicknesses make three halvings: 320 min−12×2×2=40 min−1\frac{320\,\mathrm{min^{-1}}}{2\times2\times2}=40\,\mathrm{min^{-1}}2×2×2320min−1​=40min−1.

Answer: The half-value thickness is 1.0 cm1.0\,\mathrm{cm}1.0cm, and the rate with 3.0 cm3.0\,\mathrm{cm}3.0cm is 40 min−140\,\mathrm{min^{-1}}40min−1.

Figure 1. Each extra centimetre of lead halves the corrected count rate, so the curve falls without ever reaching zero.

Key terms · tap one for its definition

shielding

Shielding is absorbing material placed between a source and people to reduce the radiation that reaches them.

half-value thickness

The half-value thickness of a material is the thickness that reduces the intensity of radiation passing through it to half.

Part 4 done

Quick check

One question on the part you just read

Easy

Identify the correct source of background radiation.
Show answer and explanation

Answer: B · Worked explanation

Background radiation comes from natural and artificial sources, including rocks, air and cosmic rays. It is present even with no source in the room. It is not limited to artificial sources such as hospitals, because natural sources are the main contributors.
5

Part 5 of 5: Safe handling combines limits, monitoring and careful storage

Precautions work only when people follow rules and check their exposure. Workers wear a dosimeter, which records the radiation they receive. A dose limit keeps the extra risk very small.

  • Handle sources with tongs, never with bare hands.
  • Store sources in labelled, locked, lead-lined containers.
  • Limit the time spent near a source.
  • Keep exposure as low as reasonably practicable.

Waste that stays radioactive for a very long time needs sealed and shielded storage.

Exam tip

When data compare a reading with a limit, quote both values with units. State clearly whether the reading is above or below the limit.

Key terms · tap one for its definition

dosimeter

A dosimeter is a device worn by a person to record the radiation exposure they receive.

dose limit

A dose limit is the maximum radiation exposure a person is allowed to receive over a stated period.

Note read

Check your recall[15 marks]

6 written questions. Answer each one in your head or on paper, then open the mark scheme.

  1. 1.State[1 mark]

    State what is meant by ionising radiation.

    Show mark schemeHide mark scheme

    Model answer

    Ionising radiation carries enough energy to remove electrons from atoms or molecules.

    • 1 mark for stating that it has enough energy to remove electrons from atoms or molecules
  2. 2.Describe[3 marks]

    Describe how ionising radiation can harm a living cell.

    Show mark schemeHide mark scheme

    Model answer

    The radiation ionises atoms and molecules in the cell. This can damage DNA. The cell may then die, or divide in an uncontrolled way and cause cancer.

    • 1 mark for stating that radiation ionises atoms or molecules in the cell
    • 1 mark for stating that DNA can be damaged
    • 1 mark for stating that the cell may die or become cancerous
  3. 3.Explain[2 marks]

    Explain why the background count rate must be measured before an experiment with a radioactive source.

    Show mark schemeHide mark scheme

    Model answer

    A detector counts ionising radiation from the surroundings even with no source present. Subtracting the background gives the count rate due to the source alone.

    • 1 mark for stating that the detector counts background radiation even without the source
    • 1 mark for stating that subtracting it gives the corrected count rate from the source alone
  4. 4.Calculate[3 marks]

    A small gamma source gives a corrected count rate of 150 min−1150\,\mathrm{min^{-1}}150min−1 at 0.40 m0.40\,\mathrm{m}0.40m. Calculate the corrected count rate at 1.2 m1.2\,\mathrm{m}1.2m.

    Show mark schemeHide mark scheme

    Model answer

    The distance is multiplied by 3, so intensity falls by a factor of 32=93^2=932=9. The rate is 150 min−19=17 min−1\frac{150\,\mathrm{min^{-1}}}{9}=17\,\mathrm{min^{-1}}9150min−1​=17min−1.

    • 1 mark for finding that the distance increases by a factor of 3
    • 1 mark for using the inverse square law to divide by 9
    • 1 mark for obtaining 17 min−117\,\mathrm{min^{-1}}17min−1
  5. 5.Describe[3 marks]

    Describe three precautions that reduce exposure when a worker handles a radioactive source.

    Show mark schemeHide mark scheme

    Model answer

    Use tongs to keep the source away from the body. Limit the time spent near it. Keep the source in a shielded container, such as one lined with lead, when it is not in use.

    • 1 mark for stating the use of tongs or distance
    • 1 mark for stating the limiting of time of exposure
    • 1 mark for stating the use of shielding or a lead-lined container
  6. 6.Suggest[3 marks]

    Suggest why an alpha source is dangerous when swallowed, even though paper stops alpha radiation.

    Show mark schemeHide mark scheme

    Model answer

    Alpha radiation is strongly ionising. Inside the body, no skin or air lies in the way, so its energy is absorbed in nearby tissue. This causes concentrated ionisation and damage to cells.

    • 1 mark for stating that alpha radiation is strongly ionising
    • 1 mark for stating that inside the body nothing separates the source from tissue
    • 1 mark for linking the absorbed energy to damage in nearby cells

Practice this topic

10 quick-fire multiple-choice questions, easy to hard. Tap an answer to see if you're right and the worked explanation. (The written questions with mark schemes are under “Check your recall” above.)

0 right0 of 10 answered

Includes the 2 quick checks in the note above.

3.

Easy·Identify[1 mark]

Identify the material that is most effective at reducing the intensity of gamma radiation.
Show answer and explanation

Answer: C · Worked explanation

Gamma rays are highly penetrating, so thick lead is needed to reduce their intensity. A sheet of paper is enough for alpha radiation but has almost no effect on gamma rays, which pass straight through it. A few cm of air also absorbs very little gamma radiation, and thin foil absorbs beta radiation rather than gamma.
4.

Medium·Calculate[1 mark]

A detector records 180 counts in 2.0 min2.0\,\mathrm{min}2.0min with a source present. The background count rate is 12 min−112\,\mathrm{min^{-1}}12min−1. Calculate the corrected count rate.
Show answer and explanation

Answer: D · Worked explanation

The measured rate is 1802.0 min=90 min−1\frac{180}{2.0\,\mathrm{min}}=90\,\mathrm{min^{-1}}2.0min180​=90min−1. Subtract the background count rate: 90−12=78 min−190-12=78\,\mathrm{min^{-1}}90−12=78min−1. The value 168 min−1168\,\mathrm{min^{-1}}168min−1 comes from subtracting 12 from the total counts instead of from the count rate. The value 102 min−1102\,\mathrm{min^{-1}}102min−1 comes from adding the background instead of subtracting it.
5.

Medium·Calculate[1 mark]

A small gamma source gives a corrected count rate of 400 min−1400\,\mathrm{min^{-1}}400min−1 at 0.30 m0.30\,\mathrm{m}0.30m. Calculate the corrected count rate at 0.90 m0.90\,\mathrm{m}0.90m.
Show answer and explanation

Answer: A · Worked explanation

The distance triples, so the intensity falls by a factor of 32=93^2=932=9: 400 min−19=44 min−1\frac{400\,\mathrm{min^{-1}}}{9}=44\,\mathrm{min^{-1}}9400min−1​=44min−1. The value 130 min−1130\,\mathrm{min^{-1}}130min−1 comes from dividing by 3, which treats intensity as inversely proportional to distance rather than to its square. The value 1200 min−11200\,\mathrm{min^{-1}}1200min−1 comes from multiplying by 3, so the rate wrongly increases.
6.

Medium·Determine[1 mark]

The corrected count rate of a gamma source falls from 480 min−1480\,\mathrm{min^{-1}}480min−1 to 120 min−1120\,\mathrm{min^{-1}}120min−1 when 4.0 mm4.0\,\mathrm{mm}4.0mm of a material is added. Determine the half-value thickness.
Show answer and explanation

Answer: B · Worked explanation

The rate falls to one quarter, which is two halvings. Two half-value thicknesses make 4.0 mm4.0\,\mathrm{mm}4.0mm, so one half-value thickness is 2.0 mm2.0\,\mathrm{mm}2.0mm. The value 4.0 mm4.0\,\mathrm{mm}4.0mm treats the whole thickness as a single halving, which would only give half the rate. The value 1.0 mm1.0\,\mathrm{mm}1.0mm divides the thickness by 4, the factor in the rate, instead of by the number of halvings.
7.

Medium·Predict[1 mark]

A worker’s dosimeter shows an exposure below the dose limit. Predict the most sensible conclusion.
Show answer and explanation

Answer: C · Worked explanation

A reading below the limit is acceptable, but good practice keeps exposure as low as reasonably practicable. Treating the limit as a target to approach is wrong, since the limit is a maximum rather than a goal. A reading below the limit gives no reason to think the dosimeter is faulty, and time, distance and shielding precautions still apply.
8.

Hard·Calculate[2 marks]

A small gamma source has a corrected count rate of 640 min−1640\,\mathrm{min^{-1}}640min−1 at 1.0 m1.0\,\mathrm{m}1.0m with no shield. A shield of thickness equal to 3 half-value thicknesses is added and the detector moves to 2.0 m2.0\,\mathrm{m}2.0m. Calculate the new corrected count rate.
Show answer and explanation

Answer: D · Worked explanation

Three half-value thicknesses divide the rate by 23=82^3=823=8, so 6408=80 min−1\frac{640}{8}=80\,\mathrm{min^{-1}}8640​=80min−1. Doubling the distance from 1.0 m1.0\,\mathrm{m}1.0m to 2.0 m2.0\,\mathrm{m}2.0m divides by 22=42^2=422=4, giving 20 min−120\,\mathrm{min^{-1}}20min−1. The value 53 comes from dividing by 3×4=123\times4=123×4=12, which uses the number of half-value thicknesses instead of the factor 23=82^3=823=8.
9.

Hard·Predict[2 marks]

A detector reads 130 min−1130\,\mathrm{min^{-1}}130min−1 at a distance xxx from a small gamma source. The background is 30 min−130\,\mathrm{min^{-1}}30min−1. Predict the reading when the distance is doubled.
Show answer and explanation

Answer: B · Worked explanation

The corrected rate is 130−30=100 min−1130-30=100\,\mathrm{min^{-1}}130−30=100min−1. Doubling the distance divides it by 4, giving 25. The detector still counts the background, so it reads 25+30=55 min−125+30=55\,\mathrm{min^{-1}}25+30=55min−1. The value 33 comes from dividing the measured rate by 4, which wrongly includes the background.
10.

Hard·Explain[2 marks]

Explain why an alpha emitter is more dangerous inside the body than outside it.
Show answer and explanation

Answer: C · Worked explanation

Alpha radiation is strongly ionising but has a very short range. Outside the body, skin or air stops it. Inside, all of its energy is absorbed in nearby cells. Alpha radiation is not more penetrating than gamma radiation, so that statement is false.

Keep going

Next topic3.9.1 TelescopesPrevious topic3.8.1.7 Induced fission

More in Section 3.8 · Nuclear physics

  1. 3.8.1.1Rutherford scatteringNotes · 10 questions
  2. 3.8.1.2Alpha, beta and gamma radiationNotes · 10 questions
  3. 3.8.1.3Radioactive decayNotes · 10 questions
  4. 3.8.1.4Nuclear instabilityNotes · 10 questions
  5. 3.8.1.5Nuclear radiusNotes · 10 questions
  6. 3.8.1.6Mass and energyNotes · 10 questions
  7. 3.8.1.7Induced fissionNotes · 10 questions
  8. 3.8.1.8Safety aspectsNotes · 10 questions

All AQA A-level Physics topics →

Draft: written by Scribe and checked automatically, not yet by a subject reviewer.

Practice questions are original, written by Scribe and checked automatically for correctness.

Topic codes follow the official numbering. Not endorsed by AQA or any exam board.

On this page

0/5 read

  1. 1Ionising radiation damages living cells
  2. 2Background radiation must be subtracted from measurements
  3. 3Increasing distance from a source sharply cuts exposure
  4. 4Thicker shielding absorbs more radiation
  5. 5Safe handling combines limits, monitoring and careful storage
  6. Check your recall
  7. Practice: 10 questions
All coursesScribeHow it worksPricingPrivacyTerms

Notes and questions are written by Scribe in our own words. Topic codes follow the official course numbering so you can find your place. Not produced or endorsed by the IB, College Board, AQA, OCR, Pearson Edexcel or any exam board.

© 2026 Scribe

Shielding and count rate

Corrected count rate (min⁻¹)012340100200300Thickness of lead (cm)
  • Gamma source
  • 320
  • 160
  • 80
  • 40