AQA A-level Physics · Section 3.10 · Option: Medical physics

3.10.3 Biological measurement

Describe how electrodes detect the heart’s electrical activity, interpret a simple ECG trace, and explain how electrode contact and placement affect it.

  • 5 min read
  • 6 parts
  • 10 questions
  • Draft
Start a Quick 5 on this topic→Jump to the 10 questions
1/6The heart produces small electrical signals as it beats
  1. 1The heart produces small electrical signals as it beats
  2. 2Skin electrodes detect tiny potential differences from the heart
  3. 3Each part of an ECG trace matches a stage of the heartbeat
  4. 4Heart rate follows from the time between successive R peaks
  5. 5Poor skin contact adds noise and weakens the signal
  6. 6Electrode position changes the shape of the trace
  7. Check your recall
  8. Practice: 10 questions
1

Part 1 of 6: The heart produces small electrical signals as it beats

A beating heart is controlled by electrical signals. Muscle cells in the heart contract when a wave of electrical change spreads through them. Doctors can detect this change from outside the body.

The change starts when charged particles move across the membrane of a heart muscle cell. Each such particle is an ion. Their movement alters the potential difference across the membrane.

This rapid change is depolarisation, and it makes the cell contract. The cell then returns to its resting state in repolarisation. Depolarisation passes from cell to cell, so a wave of it crosses the whole heart.

Key terms · tap one for its definition

ion

An ion is an atom or group of atoms with a net charge from losing or gaining electrons.

depolarisation

Depolarisation is the rapid change in potential difference across a heart muscle cell membrane that triggers the cell to contract.

repolarisation

Repolarisation is the recovery of the potential difference across a cell membrane to its resting value after depolarisation.

Part 1 done

2

Part 2 of 6: Skin electrodes detect tiny potential differences from the heart

Body fluids contain ions, so they conduct electricity. The heart’s electrical activity therefore produces small potential differences between points on the skin. These are of the order of a millivolt.

An electrode is a conductor fixed to the skin to pick up these potential differences. An electrocardiogram, or ECG, is a record of the potential difference between electrodes against time.

The signal is too small to display directly, so an amplifier increases it. A differential amplifier amplifies only the difference between its two inputs. Interference that reaches both electrodes equally, such as mains hum, is therefore largely cancelled.

Key terms · tap one for its definition

electrode

An electrode is a conductor in contact with the skin that picks up the potential difference produced by the heart.

electrocardiogram

An electrocardiogram is a graph of the potential difference between two skin electrodes plotted against time.

differential amplifier

A differential amplifier is an amplifier that amplifies the difference between its two inputs and largely rejects signals common to both.

Part 2 done

Quick check

One question on the part you just read

Easy

Identify the feature of an ECG trace caused by depolarisation of the ventricles.
Show answer and explanation

Answer: B · Worked explanation

The QRS complex is the sharp spike produced when the ventricles depolarise. The P wave is tempting, but it is the small bump produced by depolarisation of the atria. The T wave shows repolarisation of the ventricles, not depolarisation, and the baseline shows no activity.
3

Part 3 of 6: Each part of an ECG trace matches a stage of the heartbeat

Now look at one heartbeat on the trace. Three features repeat with every beat. The atria are the upper chambers of the heart and the ventricles are the lower chambers.

  • The P wave is a small bump. It shows depolarisation of the atria, which then contract.
  • The QRS complex is a sharp spike. It shows depolarisation of the ventricles, which then contract.
  • The T wave is a broader bump. It shows repolarisation of the ventricles.
Figure 1. Each heartbeat produces a P wave, a QRS complex and a T wave. The R–R interval is the time between two successive R peaks.

Common mistake

The trace shows electrical activity. It does not directly show the movement or force of the heart.

Key terms · tap one for its definition

P wave

The P wave is the feature of an ECG trace produced by depolarisation of the atria.

QRS complex

The QRS complex is the sharp spike on an ECG trace produced by depolarisation of the ventricles.

T wave

The T wave is the feature of an ECG trace produced by repolarisation of the ventricles.

Part 3 done

4

Part 4 of 6: Heart rate follows from the time between successive R peaks

The trace repeats once per beat, so its timing gives the heart rate. The R–R interval is the time between two successive R peaks. The R peak is the tallest point of the QRS complex. The heart rate is the number of beats in one minute.

A recorder moves the trace along at a steady speed. This turns a distance on the trace into a time. The heart rate in min−1\mathrm{min^{-1}}min−1 is 60tRR\frac{60}{t_\mathrm{RR}}tRR​60​, with the R–R interval tRRt_\mathrm{RR}tRR​ in seconds. Uneven spacing of R peaks shows an irregular heartbeat.

Worked example

Finding a heart rate

A trace moves at 25 mm s−125\,\mathrm{mm\,s^{-1}}25mms−1. Two successive R peaks are 20 mm20\,\mathrm{mm}20mm apart. Calculate the heart rate.
  1. 1
    Time is distance divided by speed, so tRR=dvt_\mathrm{RR}=\frac{d}{v}tRR​=vd​.
  2. 2
    Substitute: tRR=20 mm25 mm s−1=0.80 st_\mathrm{RR}=\frac{20\,\mathrm{mm}}{25\,\mathrm{mm\,s^{-1}}}=0.80\,\mathrm{s}tRR​=25mms−120mm​=0.80s.
  3. 3
    Heart rate is 60tRR\frac{60}{t_\mathrm{RR}}tRR​60​.
  4. 4
    Substitute: 600.80 s=75\frac{60}{0.80\,\mathrm{s}}=750.80s60​=75.

Answer: The heart rate is 75 min−175\,\mathrm{min^{-1}}75min−1.

Key term

R–R interval

The R–R interval is the time between two successive R peaks on an ECG trace, which equals the time for one heartbeat.

Part 4 done

Quick check

One question on the part you just read

Easy

State what an ECG electrode detects.
Show answer and explanation

Answer: B · Worked explanation

The electrical activity of the heart produces small potential differences between points on the skin. Electrodes pick these up. They do not measure pressure, temperature or reflected waves, because an electrode is simply a conductor in contact with the skin.
5

Part 5 of 6: Poor skin contact adds noise and weakens the signal

A clear trace needs good contact between electrode and skin. Dry or dead skin has a high electrical resistance, which weakens the signal. Cleaning the skin removes dead cells. A conducting gel fills tiny gaps, so it lowers the contact resistance.

Unwanted signal added to the wanted one is called noise. Poor contact makes the trace noisy. It can also make the baseline drift when the patient moves.

Common problems with ECG recording and their remedies

ProblemEffect on traceRemedy
Dry or dead skinWeak, noisy signalClean the skin and use gel
Hair on the skinPoor electrode contactShave the area
Patient moves or tensesMuscle signals and drifting baselineAsk the patient to relax and stay still
Mains pick-upRegular interferenceUse a differential amplifier
Problem
Dry or dead skin
Effect on trace
Weak, noisy signal
Remedy
Clean the skin and use gel
Problem
Hair on the skin
Effect on trace
Poor electrode contact
Remedy
Shave the area
Problem
Patient moves or tenses
Effect on trace
Muscle signals and drifting baseline
Remedy
Ask the patient to relax and stay still
Problem
Mains pick-up
Effect on trace
Regular interference
Remedy
Use a differential amplifier

Exam tip

When you explain poor contact, mention high resistance and a smaller signal compared with the noise.

Key term

noise

Noise is unwanted electrical signal added to the wanted signal, which can hide or distort the trace.

Part 5 done

6

Part 6 of 6: Electrode position changes the shape of the trace

Now consider where the electrodes go. The heart’s electrical signal spreads through the body in different directions. Electrodes at different positions therefore detect different potential differences.

Electrodes on the wrists, ankles or chest each give a different view of the same heartbeat. The size and shape of the P wave, QRS complex and T wave change with position.

For this reason, clinicians use standard positions. Traces can then be compared between patients and over time. Moving an electrode slightly can change the height of a peak without any change in the heart.

Note read

Check your recall[15 marks]

6 written questions. Answer each one in your head or on paper, then open the mark scheme.

  1. 1.Describe[3 marks]

    Describe how ECG electrodes detect the electrical activity of the heart.

    Show mark schemeHide mark scheme

    Model answer

    Movement of ions across heart muscle cell membranes changes the potential difference across them. This produces small potential differences between points on the skin. Electrodes on the skin pick up the potential difference between them, and an amplifier increases it.

    • 1 mark for stating that ion movement in heart muscle produces changing potential differences
    • 1 mark for stating that this produces small potential differences between points on the skin
    • 1 mark for stating that electrodes pick up the potential difference and an amplifier increases it
  2. 2.State[1 mark]

    State the event in the heart that produces the QRS complex.

    Show mark schemeHide mark scheme

    Model answer

    Depolarisation of the ventricles.

    • 1 mark for stating depolarisation of the ventricles
  3. 3.Calculate[3 marks]

    Calculate the heart rate when a trace moving at 25 mm s−125\,\mathrm{mm\,s^{-1}}25mms−1 shows successive R peaks 18 mm18\,\mathrm{mm}18mm apart.

    Show mark schemeHide mark scheme

    Model answer

    tRR=1825=0.72 st_\mathrm{RR}=\frac{18}{25}=0.72\,\mathrm{s}tRR​=2518​=0.72s. Heart rate =600.72=83 min−1=\frac{60}{0.72}=83\,\mathrm{min^{-1}}=0.7260​=83min−1.

    • 1 mark for dividing 18 mm by 25 mm s−125\,\mathrm{mm\,s^{-1}}25mms−1 to obtain 0.72 s
    • 1 mark for dividing 60 by the R–R interval
    • 1 mark for obtaining 83 min−183\,\mathrm{min^{-1}}83min−1
  4. 4.Explain[3 marks]

    Explain why the skin is cleaned and a conducting gel is used before attaching ECG electrodes.

    Show mark schemeHide mark scheme

    Model answer

    Cleaning removes dead skin and oils that give a high resistance. The gel fills small gaps between skin and electrode. Both lower the contact resistance, so the signal is larger and noise has less effect.

    • 1 mark for stating that cleaning removes dead skin that has high resistance
    • 1 mark for stating that the gel fills gaps between skin and electrode
    • 1 mark for explaining that the lower contact resistance gives a larger signal compared with the noise
  5. 5.Suggest[2 marks]

    Suggest why two ECG traces recorded from the same healthy person can look different.

    Show mark schemeHide mark scheme

    Model answer

    The electrodes may have been placed in different positions. Different positions detect the heart’s signal from different directions, so the shape and size of the features change.

    • 1 mark for stating that the electrode positions may differ
    • 1 mark for explaining that different positions detect the signal from different directions, changing the trace
  6. 6.Explain[3 marks]

    Explain why a differential amplifier is used to record an ECG.

    Show mark schemeHide mark scheme

    Model answer

    It amplifies the difference between the signals at two electrodes. Mains interference reaches both electrodes almost equally, so it largely cancels. The heart’s signal differs between the electrodes, so it is amplified.

    • 1 mark for stating that it amplifies the difference between two inputs
    • 1 mark for stating that interference reaches both electrodes almost equally and cancels
    • 1 mark for stating that the heart’s signal differs between the electrodes so it is amplified

Practice this topic

10 quick-fire multiple-choice questions, easy to hard. Tap an answer to see if you're right and the worked explanation. (The written questions with mark schemes are under “Check your recall” above.)

0 right0 of 10 answered

Includes the 2 quick checks in the note above.

3.

Easy·Name[1 mark]

Name the substance applied between an ECG electrode and the skin to lower the contact resistance.
Show answer and explanation

Answer: A · Worked explanation

A conducting gel fills the tiny gaps between skin and electrode. This lowers the contact resistance and gives a stronger, cleaner signal. A layer of air is exactly what the gel is there to remove, because air in the gaps has a very high resistance and would weaken the signal.
4.

Medium·Calculate[2 marks]

The R–R interval on a trace is 0.60 s. Calculate the heart rate.
Show answer and explanation

Answer: C · Worked explanation

Heart rate =60tRR=600.60=100 min−1=\frac{60}{t_\mathrm{RR}}=\frac{60}{0.60}=100\,\mathrm{min^{-1}}=tRR​60​=0.6060​=100min−1. The value 36 comes from multiplying 60 by 0.60 instead of dividing. Beats in one minute must number more than 60 when the interval between them is shorter than one second, so a rate above 60 is expected here.
5.

Medium·Calculate[2 marks]

A trace moves at 25 mm s−125\,\mathrm{mm\,s^{-1}}25mms−1 and two successive R peaks are 30 mm30\,\mathrm{mm}30mm apart. Calculate the heart rate.
Show answer and explanation

Answer: D · Worked explanation

The interval is tRR=3025=1.2 st_\mathrm{RR}=\frac{30}{25}=1.2\,\mathrm{s}tRR​=2530​=1.2s. The heart rate is 601.2=50 min−1\frac{60}{1.2}=50\,\mathrm{min^{-1}}1.260​=50min−1. The value 72 comes from multiplying 60 by 1.2 instead of dividing. A longer interval must give a lower rate, not a higher one, so multiplying cannot be right here.
6.

Medium·Suggest[2 marks]

A trace has a baseline that wanders up and down and shows irregular small spikes. Suggest the most likely cause.
Show answer and explanation

Answer: C · Worked explanation

Poor contact raises the resistance, and patient movement or muscle tension adds unwanted signals. Both give noise and a drifting baseline. A fast heart rate changes how often the features repeat, but the shape of each beat and the baseline would still be steady.
7.

Medium·Explain[2 marks]

Explain why a differential amplifier reduces mains interference in an ECG.
Show answer and explanation

Answer: D · Worked explanation

A differential amplifier amplifies the difference between its inputs. Mains interference reaches both electrodes almost equally, so the difference is close to zero. The heart’s signal differs between the electrodes, so it is amplified. Electrodes cannot select signals, so it is wrong to say they detect only the heart.
8.

Hard·Suggest[2 marks]

Two traces from the same healthy patient show different R peak heights. The electrodes were placed in different positions for the two recordings. Suggest the most reasonable conclusion.
Show answer and explanation

Answer: C · Worked explanation

The heart’s electrical signal spreads in different directions, so electrodes at different positions detect different potential differences. Peak height can then differ with no change in the heart. A weaker heart is tempting, but it cannot be concluded when the position changed, since position alone explains the difference.
9.

Hard·Calculate[2 marks]

The heart rate of a patient is 90 min−190\,\mathrm{min^{-1}}90min−1. The trace moves at 25 mm s−125\,\mathrm{mm\,s^{-1}}25mms−1. Calculate the distance between successive R peaks.
Show answer and explanation

Answer: D · Worked explanation

The interval is tRR=6090=0.67 st_\mathrm{RR}=\frac{60}{90}=0.67\,\mathrm{s}tRR​=9060​=0.67s. The distance is 25 mm s−1×0.67 s≈17 mm25\,\mathrm{mm\,s^{-1}}\times0.67\,\mathrm{s}\approx17\,\mathrm{mm}25mms−1×0.67s≈17mm. The value 38 mm comes from using 9060\frac{90}{60}6090​ as the time instead of 6090\frac{60}{90}9060​, which inverts the relationship between the rate and the interval and gives a distance that is too large.
10.

Hard·Evaluate[2 marks]

A student says, “A taller R peak shows that the ventricles are contracting more strongly.” Evaluate this statement.
Show answer and explanation

Answer: C · Worked explanation

The trace records potential difference from electrical activity, not the force of contraction. Peak height also depends on electrode position and contact. The statement is therefore not justified. The idea that the atria cause the R peak is wrong, because the QRS complex comes from depolarisation of the ventricles.

Keep going

Next topic3.10.4 Non-ionising imagingPrevious topic3.10.2 Physics of the ear

More in Section 3.10 · Option: Medical physics

  1. 3.10.1Physics of the eyeNotes · 10 questions
  2. 3.10.2Physics of the earNotes · 10 questions
  3. 3.10.3Biological measurementNotes · 10 questions
  4. 3.10.4Non-ionising imagingNotes · 10 questions
  5. 3.10.5X-ray imagingNotes · 10 questions
  6. 3.10.6Radionuclide imaging and therapyNotes · 10 questions

All AQA A-level Physics topics →

Draft: written by Scribe and checked automatically, not yet by a subject reviewer.

Practice questions are original, written by Scribe and checked automatically for correctness.

Topic codes follow the official numbering. Not endorsed by AQA or any exam board.

On this page

0/6 read

  1. 1The heart produces small electrical signals as it beats
  2. 2Skin electrodes detect tiny potential differences from the heart
  3. 3Each part of an ECG trace matches a stage of the heartbeat
  4. 4Heart rate follows from the time between successive R peaks
  5. 5Poor skin contact adds noise and weakens the signal
  6. 6Electrode position changes the shape of the trace
  7. Check your recall
  8. Practice: 10 questions
All coursesScribeHow it worksPricingPrivacyTerms

Notes and questions are written by Scribe in our own words. Topic codes follow the official course numbering so you can find your place. Not produced or endorsed by the IB, College Board, AQA, OCR, Pearson Edexcel or any exam board.

© 2026 Scribe