AQA A-level Physics · Section 3.10 · Option: Medical physics
3.10.3 Biological measurement
Describe how electrodes detect the heart’s electrical activity, interpret a simple ECG trace, and explain how electrode contact and placement affect it.
1/6The heart produces small electrical signals as it beats
- The heart produces small electrical signals as it beats
- Skin electrodes detect tiny potential differences from the heart
- Each part of an ECG trace matches a stage of the heartbeat
- Heart rate follows from the time between successive R peaks
- Poor skin contact adds noise and weakens the signal
- Electrode position changes the shape of the trace
- Check your recall
- Practice: 10 questions
Part 1 of 6: The heart produces small electrical signals as it beats
A beating heart is controlled by electrical signals. Muscle cells in the heart contract when a wave of electrical change spreads through them. Doctors can detect this change from outside the body.
The change starts when charged particles move across the membrane of a heart muscle cell. Each such particle is an ion. Their movement alters the potential difference across the membrane.
This rapid change is depolarisation, and it makes the cell contract. The cell then returns to its resting state in repolarisation. Depolarisation passes from cell to cell, so a wave of it crosses the whole heart.
Key terms · tap one for its definition
ion
An ion is an atom or group of atoms with a net charge from losing or gaining electrons.
depolarisation
Depolarisation is the rapid change in potential difference across a heart muscle cell membrane that triggers the cell to contract.
repolarisation
Repolarisation is the recovery of the potential difference across a cell membrane to its resting value after depolarisation.
Part 2 of 6: Skin electrodes detect tiny potential differences from the heart
Body fluids contain ions, so they conduct electricity. The heart’s electrical activity therefore produces small potential differences between points on the skin. These are of the order of a millivolt.
An electrode is a conductor fixed to the skin to pick up these potential differences. An electrocardiogram, or ECG, is a record of the potential difference between electrodes against time.
The signal is too small to display directly, so an amplifier increases it. A differential amplifier amplifies only the difference between its two inputs. Interference that reaches both electrodes equally, such as mains hum, is therefore largely cancelled.
Key terms · tap one for its definition
electrode
An electrode is a conductor in contact with the skin that picks up the potential difference produced by the heart.
electrocardiogram
An electrocardiogram is a graph of the potential difference between two skin electrodes plotted against time.
differential amplifier
A differential amplifier is an amplifier that amplifies the difference between its two inputs and largely rejects signals common to both.

Quick check
One question on the part you just read
Easy
Show answer and explanation
Answer: B · Worked explanation
Part 3 of 6: Each part of an ECG trace matches a stage of the heartbeat
Now look at one heartbeat on the trace. Three features repeat with every beat. The atria are the upper chambers of the heart and the ventricles are the lower chambers.
- The P wave is a small bump. It shows depolarisation of the atria, which then contract.
- The QRS complex is a sharp spike. It shows depolarisation of the ventricles, which then contract.
- The T wave is a broader bump. It shows repolarisation of the ventricles.
Key terms · tap one for its definition
P wave
The P wave is the feature of an ECG trace produced by depolarisation of the atria.
QRS complex
The QRS complex is the sharp spike on an ECG trace produced by depolarisation of the ventricles.
T wave
The T wave is the feature of an ECG trace produced by repolarisation of the ventricles.
Part 4 of 6: Heart rate follows from the time between successive R peaks
The trace repeats once per beat, so its timing gives the heart rate. The R–R interval is the time between two successive R peaks. The R peak is the tallest point of the QRS complex. The heart rate is the number of beats in one minute.
A recorder moves the trace along at a steady speed. This turns a distance on the trace into a time. The heart rate in is , with the R–R interval in seconds. Uneven spacing of R peaks shows an irregular heartbeat.
Worked example
Finding a heart rate
- Time is distance divided by speed, so .
- Substitute: .
- Heart rate is .
- Substitute: .
Answer: The heart rate is .
Key term
R–R interval
The R–R interval is the time between two successive R peaks on an ECG trace, which equals the time for one heartbeat.

Quick check
One question on the part you just read
Easy
Show answer and explanation
Answer: B · Worked explanation
Part 5 of 6: Poor skin contact adds noise and weakens the signal
A clear trace needs good contact between electrode and skin. Dry or dead skin has a high electrical resistance, which weakens the signal. Cleaning the skin removes dead cells. A conducting gel fills tiny gaps, so it lowers the contact resistance.
Unwanted signal added to the wanted one is called noise. Poor contact makes the trace noisy. It can also make the baseline drift when the patient moves.
Common problems with ECG recording and their remedies
- Problem
- Dry or dead skin
- Effect on trace
- Weak, noisy signal
- Remedy
- Clean the skin and use gel
- Problem
- Hair on the skin
- Effect on trace
- Poor electrode contact
- Remedy
- Shave the area
- Problem
- Patient moves or tenses
- Effect on trace
- Muscle signals and drifting baseline
- Remedy
- Ask the patient to relax and stay still
- Problem
- Mains pick-up
- Effect on trace
- Regular interference
- Remedy
- Use a differential amplifier
Key term
noise
Noise is unwanted electrical signal added to the wanted signal, which can hide or distort the trace.
Part 6 of 6: Electrode position changes the shape of the trace
Now consider where the electrodes go. The heart’s electrical signal spreads through the body in different directions. Electrodes at different positions therefore detect different potential differences.
Electrodes on the wrists, ankles or chest each give a different view of the same heartbeat. The size and shape of the P wave, QRS complex and T wave change with position.
For this reason, clinicians use standard positions. Traces can then be compared between patients and over time. Moving an electrode slightly can change the height of a peak without any change in the heart.
Check your recall[15 marks]
6 written questions. Answer each one in your head or on paper, then open the mark scheme.
- 1.Describe[3 marks]
Describe how ECG electrodes detect the electrical activity of the heart.
Show mark schemeHide mark scheme
Model answer
Movement of ions across heart muscle cell membranes changes the potential difference across them. This produces small potential differences between points on the skin. Electrodes on the skin pick up the potential difference between them, and an amplifier increases it.
- 1 mark for stating that ion movement in heart muscle produces changing potential differences
- 1 mark for stating that this produces small potential differences between points on the skin
- 1 mark for stating that electrodes pick up the potential difference and an amplifier increases it
- 2.State[1 mark]
State the event in the heart that produces the QRS complex.
Show mark schemeHide mark scheme
Model answer
Depolarisation of the ventricles.
- 1 mark for stating depolarisation of the ventricles
- 3.Calculate[3 marks]
Calculate the heart rate when a trace moving at shows successive R peaks apart.
Show mark schemeHide mark scheme
Model answer
. Heart rate .
- 1 mark for dividing 18 mm by to obtain 0.72 s
- 1 mark for dividing 60 by the R–R interval
- 1 mark for obtaining
- 4.Explain[3 marks]
Explain why the skin is cleaned and a conducting gel is used before attaching ECG electrodes.
Show mark schemeHide mark scheme
Model answer
Cleaning removes dead skin and oils that give a high resistance. The gel fills small gaps between skin and electrode. Both lower the contact resistance, so the signal is larger and noise has less effect.
- 1 mark for stating that cleaning removes dead skin that has high resistance
- 1 mark for stating that the gel fills gaps between skin and electrode
- 1 mark for explaining that the lower contact resistance gives a larger signal compared with the noise
- 5.Suggest[2 marks]
Suggest why two ECG traces recorded from the same healthy person can look different.
Show mark schemeHide mark scheme
Model answer
The electrodes may have been placed in different positions. Different positions detect the heart’s signal from different directions, so the shape and size of the features change.
- 1 mark for stating that the electrode positions may differ
- 1 mark for explaining that different positions detect the signal from different directions, changing the trace
- 6.Explain[3 marks]
Explain why a differential amplifier is used to record an ECG.
Show mark schemeHide mark scheme
Model answer
It amplifies the difference between the signals at two electrodes. Mains interference reaches both electrodes almost equally, so it largely cancels. The heart’s signal differs between the electrodes, so it is amplified.
- 1 mark for stating that it amplifies the difference between two inputs
- 1 mark for stating that interference reaches both electrodes almost equally and cancels
- 1 mark for stating that the heart’s signal differs between the electrodes so it is amplified

Practice this topic
10 quick-fire multiple-choice questions, easy to hard. Tap an answer to see if you're right and the worked explanation. (The written questions with mark schemes are under “Check your recall” above.)
0 right0 of 10 answered
Includes the 2 quick checks in the note above.
EasyName[1 mark]
Show answer and explanation
Answer: A · Worked explanation
MediumCalculate[2 marks]
Show answer and explanation
Answer: C · Worked explanation
MediumCalculate[2 marks]
Show answer and explanation
Answer: D · Worked explanation
MediumSuggest[2 marks]
Show answer and explanation
Answer: C · Worked explanation
MediumExplain[2 marks]
Show answer and explanation
Answer: D · Worked explanation
HardSuggest[2 marks]
Show answer and explanation
Answer: C · Worked explanation
HardCalculate[2 marks]
Show answer and explanation
Answer: D · Worked explanation
HardEvaluate[2 marks]
Show answer and explanation
Answer: C · Worked explanation