1/4Alternating current changes direction while direct current does not
  1. 1Alternating current changes direction while direct current does not
  2. 2Each wire in a plug has a different role
  3. 3The earth wire protects against a live metal case
  4. 4A fuse disconnects the live supply during a fault
  5. Check your recall
  6. Practice: 10 questions
1

Part 1 of 4: Alternating current changes direction while direct current does not

Alternating current (a.c.) repeatedly changes direction. UK mains electricity supplies a.c. to homes. Its frequency is 50 Hz. This means the current completes 50 cycles each second. During each cycle, it flows in one direction and then the other. The voltage across a mains socket is typically 230 V.

Direct current (d.c.) flows in one direction only. Cells and batteries supply d.c. Some devices use circuits that convert mains a.c. to d.c. Their plugs or power supplies may contain the parts needed for this conversion.

Common mistake

A frequency of 50 Hz means 50 complete cycles each second, not 50 changes of direction.

Key terms · tap one for its definition

Alternating current

Alternating current is electric current that repeatedly reverses direction.

frequency

Frequency is the number of complete cycles that occur each second, measured in hertz.

Direct current

Direct current is electric current that flows in one direction only.

Part 1 done

2

Part 2 of 4: Each wire in a plug has a different role

A UK three-pin plug connects an appliance to the mains. The live wire is brown and carries the alternating voltage from the supply. The neutral wire is blue and completes the circuit. The earth wire is green and yellow. It provides a safety connection to earth and normally carries no current.

Inside the plug, each wire connects to its matching pin. The earth pin is at the top. Viewed inside an opened plug, the neutral pin is on the left. The live pin is on the right. The plug also has an insulating case and a cable grip. The grip holds the outer cable securely, so a pull does not strain the wire connections.

Figure 1. The fuse is on the live side. The cable grip holds the outer cable, not the individual wires.

Key terms · tap one for its definition

live wire

The live wire carries the alternating voltage from the mains supply to an appliance.

neutral wire

The neutral wire completes the circuit between the appliance and the mains supply.

earth wire

The earth wire provides a safety path for fault current from an appliance’s metal case.

Part 2 done

Quick check

One question on the part you just read

Easy

Identify the wire in a UK three-pin plug that is connected to the metal casing of an appliance for safety.
Show answer and explanation

Answer: B · Worked explanation

The earth wire is connected to the metal casing of an appliance that has one, providing a safety path for current if the casing becomes live. The neutral wire completes the normal circuit, while the live wire supplies the potential difference; neither has the earth wire’s safety role.
3

Part 3 of 4: The earth wire protects against a live metal case

An appliance with a metal case may need earthing. Its earth wire connects the case to earth. If a fault makes the live wire touch the case, current flows through the earth wire. This creates a large fault current, which should cause the fuse to melt. The fuse then breaks the circuit, reducing the risk of an electric shock.

Some appliances have double insulation instead. Their design keeps users from touching parts that could become live, even if one layer of insulation fails. These appliances do not need an earth wire. Earthing is not a replacement for insulation: the live wire must still be covered and kept separate from the case.

Key terms · tap one for its definition

earthing

Earthing connects an appliance’s metal case to earth through a safety wire.

double insulation

Double insulation keeps users from touching live parts even if one insulating layer fails.

Part 3 done

4

Part 4 of 4: A fuse disconnects the live supply during a fault

A fuse contains a thin wire that melts if the current becomes too large. It is connected in the live side of the plug. When it melts, the circuit breaks and the appliance loses its live supply. This can happen if an appliance develops a fault.

The fuse rating should be above the appliance’s normal operating current, but low enough to protect its cable. A fuse with too low a rating may melt during normal use. One with too high a rating may not disconnect a dangerous current soon enough. The cable grip provides a different kind of protection: it stops pulling on the cable from loosening its connections.

Exam tip

When explaining an earth fault, link the live case to the large current, melted fuse and broken circuit.

Key terms · tap one for its definition

fuse

A fuse breaks a circuit when excessive current melts its thin wire.

cable grip

A cable grip secures the outer cable so pulling does not strain the wire connections.

Note read

Check your recall[14 marks]

5 written questions. Answer each one in your head or on paper, then open the mark scheme.

  1. 1.State[2 marks]

    State the typical voltage and frequency of UK mains electricity.

    Show mark schemeHide mark scheme

    Model answer

    UK mains electricity is typically 230 V at 50 Hz.

    • 1 mark for stating a typical voltage of 230 V
    • 1 mark for stating a frequency of 50 Hz
  2. 2.Compare[2 marks]

    Compare the direction of current in a.c. and d.c.

    Show mark schemeHide mark scheme

    Model answer

    A.c. repeatedly changes direction, while d.c. flows in one direction only.

    • 1 mark for stating that a.c. repeatedly changes direction
    • 1 mark for stating that d.c. flows in one direction only
  3. 3.Identify[3 marks]

    Identify the three plug wires by colour and give each function.

    Show mark schemeHide mark scheme

    Model answer

    The brown live wire carries the supply voltage. The blue neutral wire completes the circuit. The green-and-yellow earth wire provides a safety path for fault current.

    • 1 mark for identifying the brown live wire as carrying the supply voltage
    • 1 mark for identifying the blue neutral wire as completing the circuit
    • 1 mark for identifying the green-and-yellow earth wire as providing a safety path for fault current
  4. 4.Explain[4 marks]

    Explain how the earth wire and fuse protect someone if a live wire touches an appliance’s metal case.

    Show mark schemeHide mark scheme

    Model answer

    The earth wire connects the case to earth. If the live wire touches the case, a large current flows through the earth wire. This melts the fuse, breaking the circuit and reducing the risk of electric shock.

    • 1 mark for stating that the earth wire connects the metal case to earth
    • 1 mark for explaining that a fault causes a large current through the earth wire
    • 1 mark for stating that the large current melts the fuse
    • 1 mark for explaining that the broken circuit reduces the risk of electric shock
  5. 5.Describe[3 marks]

    Describe the roles of the fuse and cable grip in a plug.

    Show mark schemeHide mark scheme

    Model answer

    The fuse is connected in the live side and melts if the current becomes too large. The cable grip holds the outer cable, preventing a pull from loosening the wire connections.

    • 1 mark for stating that the fuse is connected in the live side
    • 1 mark for stating that the fuse melts and breaks the circuit if current becomes too large
    • 1 mark for stating that the cable grip prevents pulling on the cable from straining the wire connections

Practice this topic

10 quick-fire multiple-choice questions, easy to hard. Tap an answer to see if you're right and the worked explanation. (The written questions with mark schemes are under “Check your recall” above.)

0 right0 of 10 answered

Includes the quick check in the note above.

2.

Easy·State[1 mark]

State the usual colour of the live wire in a modern UK plug.
Show answer and explanation

Answer: B · Worked explanation

The live wire in a modern UK plug is brown. Blue identifies the neutral wire, and green and yellow identify the earth wire. Black is not the modern UK colour for the live wire.
3.

Easy·Identify[1 mark]

Identify the type of current in which charge flows in one direction only.
Show answer and explanation

Answer: A · Worked explanation

Direct current (d.c.) flows in one direction only. Alternating current (a.c.) repeatedly changes direction, which is why the two types of current are distinguished by how their direction changes over time.
4.

Easy·State[1 mark]

State the typical frequency of UK mains electricity.
Show answer and explanation

Answer: B · Worked explanation

The typical frequency of UK mains electricity is 50 Hz50\,\text{Hz}50Hz. This means the a.c. completes 50 cycles each second. The value 230 is the typical mains voltage in volts, not its frequency.
5.

Medium·Identify[1 mark]

A plug is wired using modern UK colours. Which wire should be connected to the terminal marked N?
Show answer and explanation

Answer: B · Worked explanation

The terminal marked N is the neutral terminal, and the neutral wire is blue in a modern UK plug. Brown is live and green and yellow is earth. The fuse is connected in the live side of the plug, not used to identify the neutral wire.
6.

Medium·Explain[2 marks]

A fault makes the metal casing of an earthed appliance live. Explain how the earth wire and fuse help reduce the risk of electric shock.
Show answer and explanation

Answer: B · Worked explanation

The earth wire provides a low-resistance path from the faulty casing, allowing a large current to flow. This current melts the fuse and breaks the circuit, disconnecting the supply and reducing the chance of someone receiving a shock. The earth wire does not simply prevent all current from flowing.
7.

Medium·Compare[2 marks]

A battery-powered device is connected to an oscilloscope and its current is monitored. Which description distinguishes its direct current from UK mains current?
Show answer and explanation

Answer: D · Worked explanation

A battery supplies direct current, which flows in one direction, whereas UK mains supplies alternating current, which repeatedly reverses direction. The distinction is about direction, not simply voltage: a.c. has a frequency because it cycles, but that does not make d.c. flow in both directions.
8.

Medium·Calculate[2 marks]

UK mains completes 50 cycles each second. How many cycles does it complete in 4 seconds?
Show answer and explanation

Answer: A · Worked explanation

Multiply the frequency by the time: 50 cycles s−1×4 s=20050\,\text{cycles s}^{-1} \times 4\,\text{s} = 20050cycles s−1×4s=200 cycles. The frequency is the number of cycles per second, so multiplying by 4 seconds gives the total number of cycles, not a frequency in hertz.
9.

Medium·Determine[2 marks]

An appliance normally draws 4.2 A4.2\,\text{A}4.2A. Its manufacturer recommends a fuse rated just above this current. Which fuse is the best choice from 3 A3\,\text{A}3A, 5 A5\,\text{A}5A, and 13 A13\,\text{A}13A?
Show answer and explanation

Answer: A · Worked explanation

The fuse should be rated just above the appliance’s normal current of 4.2 A4.2\,\text{A}4.2A, so the 5 A5\,\text{A}5A fuse is the best choice. A 3 A3\,\text{A}3A fuse could melt during normal operation, while a 13 A13\,\text{A}13A fuse would allow a larger current before breaking the circuit.
10.

Medium·Identify[1 mark]

Which part of a UK three-pin plug is designed to melt and break the circuit if the current becomes too large?
Show answer and explanation

Answer: C · Worked explanation

The fuse contains a wire that melts if an excessive current flows, breaking the circuit and disconnecting the supply. The earth pin connects to the safety earth wire, while the cable grip holds the cable in place; neither is designed to melt as an overcurrent protection device.

Keep going

Next topic6.2.4 Energy transfers in circuitsPrevious topic6.2.2 Series and parallel circuits

More in Section 6.2 · Physics: Electricity

  1. 6.2.1Current, potential difference and resistanceNotes · 10 questions
  2. 6.2.2Series and parallel circuitsNotes · 10 questions
  3. 6.2.3Domestic electricityNotes · 10 questions
  4. 6.2.4Energy transfers in circuitsNotes · 10 questions

All AQA GCSE Combined Science: Trilogy topics →

Draft: written by Scribe and checked automatically, not yet by a subject reviewer.

Practice questions are original, written by Scribe and checked automatically for correctness.

Topic codes follow the official numbering. Not endorsed by AQA or any exam board.

On this page

0/4 read

  1. 1Alternating current changes direction while direct current does not
  2. 2Each wire in a plug has a different role
  3. 3The earth wire protects against a live metal case
  4. 4A fuse disconnects the live supply during a fault
  5. Check your recall
  6. Practice: 10 questions
All coursesScribeHow it worksPricingPrivacyTerms

Notes and questions are written by Scribe in our own words. Topic codes follow the official course numbering so you can find your place. Not produced or endorsed by the IB, College Board, AQA, OCR, Pearson Edexcel or any exam board.

© 2026 Scribe