Scribe logoScribeNotes & practice
Sign inStart free
  1. Notes
  2. ›AQA A-level Chemistry
  3. ›3.3 Organic chemistry
  4. ›3.3.16 Chromatography

AQA A-level Chemistry · Section 3.3 · Organic chemistry

3.3.16 Chromatography

Describe thin-layer and gas chromatography, calculate Rf values, interpret chromatograms and explain how chromatography is used in analysis.

  • 5 min read
  • 5 parts
  • 10 questions
  • Draft
Start a Quick 5 on this topic→Jump to the 10 questions
1/5Chromatography separates a mixture using two phases
  1. 1Chromatography separates a mixture using two phases
  2. 2Thin-layer chromatography separates spots on a coated plate
  3. 3Rf values let you compare spots reliably
  4. 4Gas chromatography separates volatile mixtures by retention time
  5. 5Chromatography identifies and measures components in real samples
  6. Check your recall
  7. Practice: 10 questions
1

Part 1 of 5: Chromatography separates a mixture using two phases

A drop of ink on wet paper spreads into bands of different colour. That is chromatography in its simplest form. Every method uses two phases.

The stationary phase stays in place. The mobile phase moves through or over it and carries the mixture along.

Each component moves back and forth between the two phases. A component held strongly by the stationary phase spends more time stuck, so it moves slowly. A component that favours the mobile phase moves faster. These different speeds separate the mixture.

Common mistake

The stationary phase is not always a plain solid. In gas chromatography it is a liquid coated on a solid, but it still stays fixed in place.

Key terms · tap one for its definition

stationary phase

The stationary phase is the solid, or a liquid coated on a solid, that stays fixed while the mobile phase moves past it.

mobile phase

The mobile phase is the liquid or gas that carries the components of a mixture through or over the stationary phase.

Part 1 done

2

Part 2 of 5: Thin-layer chromatography separates spots on a coated plate

Now apply the idea to a flat plate. In thin-layer chromatography (TLC), the stationary phase is a thin layer of solid on a plate, usually silica. The mobile phase is a liquid solvent.

Components stick to the silica by adsorption. A component that adsorbs strongly travels a short distance. One that adsorbs weakly travels further with the solvent.

  • Draw a pencil line near the bottom of the plate and add a small spot of sample.
  • Stand the plate in a covered beaker with the solvent level below the line.
  • Remove the plate near the top and mark the solvent front at once.
  • Dry the plate and make colourless spots visible, for example with ultraviolet light.

Common mistake

Draw the origin line in pencil, never ink. Ink would dissolve in the solvent and run up the plate.

Key terms · tap one for its definition

thin-layer chromatography

Thin-layer chromatography is a method using a plate coated with solid stationary phase and a liquid solvent as the mobile phase.

adsorption

Adsorption is the attachment of molecules to the surface of a solid by weak attractions, such as hydrogen bonds or van der Waals forces.

solvent front

The solvent front is the furthest point reached by the solvent on a TLC plate, marked before the plate dries.

Part 2 done

Quick check

One question on the part you just read

Easy

Identify the pair that correctly describes the phases in gas chromatography.
Show answer and explanation

Answer: B · Worked explanation

In gas chromatography the mobile phase is an unreactive carrier gas, and the stationary phase is a liquid coated on a solid inside the column. Solid silica with a liquid solvent describes thin-layer chromatography instead. Reversing the phases is a common slip.
3

Part 3 of 5: Rf values let you compare spots reliably

Once the plate is dry, you need numbers to compare spots from different runs. Measure from the origin line to the centre of a spot, then from the origin line to the solvent front. The Rf value is the ratio of these two distances.

Rf=dspotdfrontR_\mathrm{f}=\frac{d_\mathrm{spot}}{d_\mathrm{front}}Rf​=dfront​dspot​​, where dspotd_\mathrm{spot}dspot​ is the distance moved by the spot and dfrontd_\mathrm{front}dfront​ is the distance moved by the solvent front.

An Rf value has no units and lies between 0 and 1. It depends on the solvent and the stationary phase. Compare values only from identical conditions, ideally with known compounds on the same plate.

Figure 1. Spots that travel the same distance in the same solvent may be the same compound. Each Rf value comes from distances measured from the origin.

Worked example

Calculating an Rf value

The origin line is 1.0 cm above the bottom edge of a plate. After the run, the solvent front is 7.4 cm above the bottom edge. A spot centre is 3.4 cm above the bottom edge. Calculate the Rf value.
  1. 1
    Rf is the distance moved by the spot divided by the distance moved by the solvent front.
  2. 2
    Both distances are measured from the origin: dfront=7.4−1.0=6.4 cmd_\mathrm{front}=7.4-1.0=6.4\,\mathrm{cm}dfront​=7.4−1.0=6.4cm and dspot=3.4−1.0=2.4 cmd_\mathrm{spot}=3.4-1.0=2.4\,\mathrm{cm}dspot​=3.4−1.0=2.4cm.
  3. 3
    Rf=2.46.4=0.375R_\mathrm{f}=\frac{2.4}{6.4}=0.375Rf​=6.42.4​=0.375, which is 0.38 to 2 significant figures.

Answer: Rf≈0.38R_\mathrm{f}\approx0.38Rf​≈0.38, with no units.

Common mistake

Measure both distances from the origin line, not from the bottom edge of the plate.

Key term

Rf value

The Rf value is the distance moved by a spot divided by the distance moved by the solvent front, both measured from the origin.

Part 3 done

4

Part 4 of 5: Gas chromatography separates volatile mixtures by retention time

TLC suits mixtures that dissolve in a solvent. A volatile mixture is better analysed as a gas. In gas chromatography (GC), a small sample is injected into a heated oven and vaporised. An unreactive carrier gas, such as helium or nitrogen, sweeps it along a long column.

The carrier gas is the mobile phase. The stationary phase is a liquid coated on a solid inside the column.

Figure 2. Each peak is one component. Its position on the time axis is its retention time, and a larger area means more of that component.

Components that interact strongly with the stationary phase leave the column later. A detector records each one as a peak. The retention time is read from the horizontal axis. The area under each peak shows the relative amount of that component.

Comparing thin-layer and gas chromatography

FeatureThin-layerGas
Stationary phaseSolid on a plateLiquid on a solid in a column
Mobile phaseLiquid solventCarrier gas
SampleDissolves in the solventVolatile mixture
ResultSpots and Rf valuesPeaks and retention times
Feature
Stationary phase
Thin-layer
Solid on a plate
Gas
Liquid on a solid in a column
Feature
Mobile phase
Thin-layer
Liquid solvent
Gas
Carrier gas
Feature
Sample
Thin-layer
Dissolves in the solvent
Gas
Volatile mixture
Feature
Result
Thin-layer
Spots and Rf values
Gas
Peaks and retention times

Key terms · tap one for its definition

gas chromatography

Gas chromatography is a method in which a vaporised sample is carried by an unreactive gas through a column holding a liquid stationary phase.

retention time

The retention time is the time taken for a component to travel from the point of injection to the detector.

Part 4 done

Quick check

One question on the part you just read

Easy

State which statement about Rf values is correct.
Show answer and explanation

Answer: C · Worked explanation

An Rf value is a ratio of two distances, so the units cancel and it has no units. A spot cannot travel further than the solvent front, so the value lies between 0 and 1. It does change with the solvent, so it is not the same in every solvent.
5

Part 5 of 5: Chromatography identifies and measures components in real samples

Separation is only useful if you can say what each component is. In GC–MS, a gas chromatograph separates the mixture and a mass spectrometer identifies each component as it leaves the column.

Uses include testing sports samples for banned drugs, finding pollutants in water and checking food for additives. Chemists also use TLC to see whether a reaction has finished or a product is pure.

Exam tip

One spot or one peak suggests purity but does not prove it. Two different compounds can share an Rf value or a retention time.

Worked example

Percentage composition from peak areas

A gas chromatogram of a fuel sample shows three peaks with areas 12, 30 and 18 units. The detector responds equally to all three components. Calculate the percentage of the sample that is the largest component.
  1. 1
    Percentage = peak area divided by total area, multiplied by 100.
  2. 2
    Total area =12+30+18=60=12+30+18=60=12+30+18=60 units.
  3. 3
    3060×100=50%\frac{30}{60}\times100=50\%6030​×100=50%

Answer: The largest component makes up 50% of the sample.

Go deeperColumn chromatography uses the same idea on a larger scale

In column chromatography, a glass tube is packed with a solid such as silica or alumina. A solution of the mixture is added at the top, and solvent runs down through the column.

Weakly adsorbed components emerge first, and each is collected in a separate portion. The method can separate enough material to isolate a pure product.

Key term

GC–MS

GC–MS is a combined technique in which gas chromatography separates a mixture and mass spectrometry identifies each component.

Note read

Check your recall[14 marks]

6 written questions. Answer each one in your head or on paper, then open the mark scheme.

  1. 1.Describe[3 marks]

    Describe how thin-layer chromatography separates the components of a mixture.

    Show mark schemeHide mark scheme

    Model answer

    A spot of the mixture is placed on a pencil origin line on a plate coated with a solid stationary phase. The solvent, the mobile phase, rises up the plate and carries the components. Components that adsorb more strongly on the solid move less far, so they separate.

    • 1 mark for placing a spot of mixture on a pencil origin line on a coated plate
    • 1 mark for stating that the solvent (mobile phase) rises up the plate carrying the components
    • 1 mark for stating that components adsorb to different extents so travel different distances
  2. 2.Calculate[2 marks]

    Calculate the Rf value of a spot that moves 3.6 cm from the origin when the solvent front moves 8.0 cm from the origin.

    Show mark schemeHide mark scheme

    Model answer

    Rf=3.68.0=0.45R_\mathrm{f}=\frac{3.6}{8.0}=0.45Rf​=8.03.6​=0.45, with no units.

    • 1 mark for dividing the distance moved by the spot by the distance moved by the solvent front
    • 1 mark for obtaining 0.45 with no units
  3. 3.Explain[3 marks]

    Explain why different components of a mixture have different retention times in gas chromatography.

    Show mark schemeHide mark scheme

    Model answer

    Components interact with the liquid stationary phase to different extents. A component that interacts more strongly spends more time held by the stationary phase. It therefore leaves the column later and has a longer retention time.

    • 1 mark for stating that components interact with the stationary phase to different extents
    • 1 mark for stating that stronger interaction means more time held by the stationary phase
    • 1 mark for linking this to leaving the column later and a longer retention time
  4. 4.State[1 mark]

    State why the origin line on a TLC plate is drawn in pencil rather than ink.

    Show mark schemeHide mark scheme

    Model answer

    Ink would dissolve in the solvent and run up the plate with the sample.

    • 1 mark for stating that ink would dissolve in the solvent and run up the plate
  5. 5.Suggest[3 marks]

    Suggest why a single spot on a TLC plate does not prove that a product is pure, and suggest one further test.

    Show mark schemeHide mark scheme

    Model answer

    A second compound could have the same Rf value in that solvent, so it would give a spot in the same place. Running the plate again in a different solvent would test this. GC–MS could also be used.

    • 1 mark for stating that another compound could have the same Rf value in that solvent
    • 1 mark for stating that only one spot may therefore be seen
    • 1 mark for suggesting a further test, such as a different solvent or GC–MS
  6. 6.Calculate[2 marks]

    Calculate the percentage of the mixture that is the component with the smallest peak area. The gas chromatogram has peak areas of 8.0, 20.0 and 12.0 units, and the detector responds equally to all components.

    Show mark schemeHide mark scheme

    Model answer

    Total area =8.0+20.0+12.0=40.0=8.0+20.0+12.0=40.0=8.0+20.0+12.0=40.0 units. Percentage =8.040.0×100=20%=\frac{8.0}{40.0}\times100=20\%=40.08.0​×100=20%.

    • 1 mark for finding the total area of 40.0 units
    • 1 mark for dividing 8.0 by the total and multiplying by 100 to give 20%

Practice this topic

10 quick-fire multiple-choice questions, easy to hard. Tap an answer to see if you're right and the worked explanation. (The written questions with mark schemes are under “Check your recall” above.)

0 right0 of 10 answered

Includes the 2 quick checks in the note above.

3.

Easy[1 mark]

Why must the solvent level in a TLC beaker be below the origin line?
Show answer and explanation

Answer: D · Worked explanation

The sample must start on the plate to be carried up it. If the solvent covered the origin line, the sample would dissolve into the solvent in the beaker instead. Raising the level would not speed up the run, and the silica stationary phase does not dissolve.
4.

Medium·Determine[2 marks]

The origin line on a TLC plate is 1.5 cm above the bottom edge. The solvent front is 9.5 cm above the bottom edge and a spot centre is 5.5 cm above the bottom edge. Determine the Rf value.
Show answer and explanation

Answer: B · Worked explanation

Measure from the origin line: the front moved 9.5−1.5=8.09.5-1.5=8.09.5−1.5=8.0 cm and the spot moved 5.5−1.5=4.05.5-1.5=4.05.5−1.5=4.0 cm. Rf=4.08.0=0.50R_\mathrm{f}=\frac{4.0}{8.0}=0.50Rf​=8.04.0​=0.50. The value 0.58 comes from measuring from the bottom edge instead, and 2.0 comes from inverting the ratio. The value 0.42 mixes one distance from the origin with one from the bottom edge.
5.

Medium·Identify[1 mark]

In a gas chromatogram, component X has a retention time of 2.4 min and component Y has a retention time of 5.1 min. Identify the correct conclusion.
Show answer and explanation

Answer: A · Worked explanation

A longer retention time means a component spent more time held by the stationary phase before reaching the detector. Y, at 5.1 min, therefore interacts more strongly with the stationary phase than X. Peak area shows the amount of a component, not its retention time, and it cannot explain which component emerges first.
6.

Medium·Calculate[2 marks]

A gas chromatogram has peak areas of 6.0, 15.0 and 9.0 units, and the detector responds equally to all components. Calculate the percentage of the mixture given by the peak of area 9.0.
Show answer and explanation

Answer: D · Worked explanation

The total area is 6.0+15.0+9.0=30.06.0+15.0+9.0=30.06.0+15.0+9.0=30.0 units. The percentage is 9.030.0×100=30%\frac{9.0}{30.0}\times100=30\%30.09.0​×100=30%. The value 33% would assume three equal components, 60% divides by the middle peak instead of the total, and 9.0% reads the area as a percentage. Only dividing by the total of all three areas gives the share of the whole mixture.
7.

Medium·Identify[1 mark]

On a silica TLC plate, two components of a mixture have Rf values of 0.25 and 0.70. Identify the component held more strongly by the silica.
Show answer and explanation

Answer: B · Worked explanation

Components that adsorb strongly onto silica are held back, so they travel less far and have a lower Rf value. The component with an Rf value of 0.25 is therefore held more strongly. Rf compares distances moved relative to the solvent front, and it is not decided only by the mass of the component. Two spots can differ in Rf at the same mass.
8.

Hard·Predict[2 marks]

A student finds that an unknown spot and a known compound have the same Rf value in one solvent. What is the best conclusion?
Show answer and explanation

Answer: C · Worked explanation

Matching values are consistent with the same compound but do not prove it, because different compounds can have the same Rf in one solvent. Repeating in a different solvent, or using GC–MS, gives stronger evidence. Comparing spots run under identical conditions on one plate is the usual basis for TLC identification, so Rf values can be compared between spots on the same plate.
9.

Hard·Predict[2 marks]

A forensic analyst finds a peak in a gas chromatogram with the same retention time as a banned drug standard. Predict which step would best confirm the identity of the compound.
Show answer and explanation

Answer: C · Worked explanation

Matching retention time alone does not prove identity because different compounds can share one. GC–MS passes each separated component into a mass spectrometer, which gives information about its structure. Repeating the run only shows reproducibility, and a larger peak area shows more sample, not a different identity.
10.

Hard·Calculate[2 marks]

In a TLC run the solvent front has moved 7.0 cm from the origin. Two spots have Rf values of 0.30 and 0.60. Calculate the distance between the centres of the two spots.
Show answer and explanation

Answer: D · Worked explanation

The distance moved is Rf×dfrontR_\mathrm{f}\times d_\mathrm{front}Rf​×dfront​, so the spots moved 0.30×7.0=2.10.30\times7.0=2.10.30×7.0=2.1 cm and 0.60×7.0=4.20.60\times7.0=4.20.60×7.0=4.2 cm. The gap is 4.2−2.1=2.14.2-2.1=2.14.2−2.1=2.1 cm. A value of 0.30 cm subtracts the Rf values without scaling by the distance moved by the solvent front, and 6.3 cm adds the two distances instead of subtracting.

Keep going

Previous topic3.3.15 NMR spectroscopy

More in Section 3.3 · Organic chemistry

  1. 3.3.8Aldehydes and ketonesNotes · 10 questions
  2. 3.3.9Carboxylic acids and derivativesNotes · 10 questions
  3. 3.3.10Aromatic chemistryNotes · 10 questions
  4. 3.3.11AminesNotes · 10 questions
  5. 3.3.12PolymersNotes · 10 questions
  6. 3.3.13Amino acids, proteins and DNANotes · 10 questions
  7. 3.3.14Organic synthesisNotes · 10 questions
  8. 3.3.15NMR spectroscopyNotes · 9 questions
  9. 3.3.16ChromatographyNotes · 10 questions

All AQA A-level Chemistry topics →

Draft: written by Scribe and checked automatically, not yet by a subject reviewer.

Practice questions are original, written by Scribe and checked automatically for correctness.

Topic codes follow the official numbering. Not endorsed by AQA or any exam board.

On this page

0/5 read

  1. 1Chromatography separates a mixture using two phases
  2. 2Thin-layer chromatography separates spots on a coated plate
  3. 3Rf values let you compare spots reliably
  4. 4Gas chromatography separates volatile mixtures by retention time
  5. 5Chromatography identifies and measures components in real samples
  6. Check your recall
  7. Practice: 10 questions
All coursesScribeHow it worksPricingPrivacyTerms

Notes and questions are written by Scribe in our own words. Topic codes follow the official course numbering so you can find your place. Not produced or endorsed by the IB, College Board, AQA, OCR, Pearson Edexcel or any exam board.

© 2026 Scribe